    Steam trap sizing

    A trap does not pass condensate — it passes a flashing mixture, because the pressure drops across the orifice and part of the condensate re-evaporates on the way through. Sizing on the liquid flow alone undersizes the trap, and it shows up as water logging rather than as a calculation error. The return line has to carry the flash, not the condensate.

    SuitableYesFlash17%ΔP7.5 bar
    Design capacity
    1,000 kg/h
    2.0× the 500 kg/h load
    Orifice
    3.8 mm
    at the trap differential
    Flash steam
    83 kg/h
    16.5% of the condensate
    Return line
    DN 80
    79 mm bore at 15 m/s
    The trap and what follows it
    The trap passes condensate; the return line carries the flash. Sizing them on the same number is the classic error.
    DN 80
    The trap and what follows it
    QuantityValueNote
    Condensate load500 kg/has entered
    Safety factor2.0×start-up and fouling
    Design capacity1,000 kg/hwhat the trap must pass
    Steam pressure8.0 barupstream
    Return pressure0.50 bardownstream
    Orifice3.80 mmliquid orifice equation
    Flash fraction16.50%(h_f1 − h_f2)/h_fg2
    Flash flow83 kg/hvapour formed
    Flash volume267 m³/hat the return pressure
    Return bore79 mmat 15 m/s
    Nominal returnDN 80next standard size
    Trap typefloatsuits this duty

    The trap passes 1000 kg/h of condensate, of which 83 kg/h flashes to steam at the return pressure — 267.4 m³/h of vapour that the return line has to carry. That is why the return line is sized on the flash, not the condensate.

    Inspect the model
    Choose a quick result view, a scaled comparison, or the complete diagnostic set.
    Flash fraction against steam pressure
    Rises with the supply pressure, because more energy has to be released at the trap.
    Flash fraction against steam pressure0.0005.0210.0515.0720.0925.122 bar2 bar5 bar5 bar8 bar8 bar12 bar12 bar16 bar16 bar% flashed
    Orifice against load
    The orifice goes as the square root of the load, so doubling the condensate needs only 41% more diameter.
    Orifice against load0.0001.793.585.387.178.962.682502503.805005005.371,0001,0007.592,0002,000mm
    Canonical equations
    The exact relationships implemented by this engine.

    ṁ = 0.65 A √(2ρΔP) · Liquid discharge.

    (h_f1 − h_f2)/h_fg2 · Energy balance.

    A = V̇/v · At 15 m/s.

    load × safety factor · 2× is typical.

    engineering methodology

    A clear path from inputs to results.

    A trap does not pass condensate — it passes a flashing mixture, because the pressure drops across the orifice and part of the condensate re-evaporates on the way through. Sizing on the liquid flow alone undersizes the trap.

    Step-by-step methodWorked exampleAssumptions explained

    How to use

    1. Enter the condensate load.
    2. Set the steam and return pressures.
    3. Choose a safety factor and a trap type.
    4. Read the orifice, the flash fraction and the return line size.

    The formula

    m˙=0.65 A2ρΔP  ;  x=hf1−hf2hfg2\dot m = 0.65\,A\sqrt{2\rho\Delta P} \;;\; x = \frac{h_{f1} - h_{f2}}{h_{fg2}}

    Reference: Liquid orifice discharge for trap capacity; flash from the saturated steam table (IAPWS-IF97).

    Worked example

    500 kg/h at 8 bar to 0.5 bar

    Inputs
    • 500 kg/h condensate, 8 bar steam, 0.5 bar return.
    • Safety factor 2, float trap.
    Calculation path
    1. 1

      The design capacity is 1,000 kg/h.

    2. 2

      Across 7.5 bar the orifice works out at 3.8 mm.

    3. 3

      The flash fraction is (721.0 − 340.5)/2305.4 = 16.5%.

    4. 4

      That is 82.5 kg/h of flash, occupying 267 m³/h at the return pressure.

    5. 5

      At 15 m/s the return line needs a 79 mm bore, so DN 80.

    Result

    3.8 mm orifice · 16.5% flash · DN 80 return.

    Interpreting the result

    The return line is the part people get wrong. The flash is only a sixth of the mass but it is most of the volume, so a return line sized on the condensate flow will be far too small and will run with a two-phase mixture at high velocity.

    Assumptions & limitations

    • Saturated condensate at the trap inlet.
    • A discharge coefficient of 0.65.
    • No heat loss between the trap and the return line.
    • A single trap, not a group.

    Frequently asked questions

    Why the safety factor?

    Because a trap must pass the start-up load, which is often two or three times the running load, and because the orifice fouls over time. 2× is conventional.

    Why does the flash matter for the return line?

    Because vapour occupies hundreds of times the volume of the liquid. A return line sized on condensate will be two-phase and noisy, and will back up the traps.

    Does back pressure affect the trap?

    Enormously. A thermodynamic trap stops cycling if the back pressure approaches the inlet pressure, and a float trap loses capacity as the differential falls.

    Which trap type should I use?

    Float-thermostatic for a modulating load, thermodynamic for high pressure and superheat, thermostatic for small loads where live steam loss matters.

    Can I recover the flash?

    Yes — a flash vessel takes the vapour off at an intermediate pressure and returns it to a low-pressure main. The flash-steam page values it.

    Methodology last reviewed 2026-10-22. Results are informational and not financial or engineering advice — see our disclaimer.