Skip to content

    Under active development. New calculators and features ship every week. Everything currently runs free while the site matures — pricing pages are a preview, checkout is not open yet.

    Calculates locally in your browser · expansion and restraint stress
    Materials / thermoelasticity

    Thermal expansion

    Compute how much a member grows when it heats up, and the stress it develops if that growth is restrained. The second number is usually the one that cracks welds and shears anchors.

    ΔT60.0 KStress stateCompressionα12.0 µm/m·K
    Length change
    8.640 mm
    New length 12.0086 m
    Thermal strain
    720.0 µε
    Dimensionless, α·ΔT
    Restrained stress
    144.00 MPa
    If both ends are fully fixed
    Restraint force
    360.0 kN
    Over 2500 mm² of section
    Expansion by material
    Length change for a 12.00 m member over ΔT = 60.0 K.
    α = 12.0 µm/m·K
    Expansion by material
    Materialα (µm/m·K)E (GPa)ΔL (mm)Restrained stress
    Carbon steel12.02008.640144.0 MPa
    Stainless 30417.319312.456200.3 MPa
    Aluminium23.16916.63295.6 MPa
    Copper16.511711.880115.8 MPa
    Concrete10.0307.20018.0 MPa
    Soda glass9.0706.48037.8 MPa
    Titanium8.61146.19258.8 MPa
    Invar 361.21410.86410.2 MPa

    Restrained stress depends only on α, E and ΔT — not on length. A stiffer or more expansive material fails first.

    Inspect the model
    Choose a quick result view, a scaled comparison, or the complete diagnostic set.
    Expansion by material
    Length change for the same member geometry across eight materials.
    Expansion by material0.0003.937.8511.7815.7019.638.64CarbonCarbon12.46StainlessStainless16.63AluminiumAluminium11.88CopperCopper7.20ConcreteConcrete6.48SodaSoda6.19TitaniumTitanium0.864InvarInvarΔL (mm)
    Length change vs temperature rise
    Expansion is linear in ΔT, so the plot is a straight line through zero.
    Length change vs temperature rise-7.830.3238.4816.6324.7932.95-40 K-40 K0 K0 K20 K20 K60 K60 K100 K100 K150 K150 K200 K200 KΔL (mm)
    Canonical equations
    The exact relationships implemented by this engine.

    ΔL = α·L·ΔT · α in 1/K, L in metres

    ε = α·ΔT · independent of length

    σ = E·α·ΔT · full restraint, elastic range

    F = σ·A · what the anchors must resist

    engineering methodology

    A clear path from inputs to results.

    A heated member grows by αLΔT. If it is free to grow, that is the end of the story. If it is restrained, the same growth becomes a stress of EαΔT — a number that reaches yield surprisingly quickly and is the reason expansion joints exist.

    Step-by-step methodWorked exampleAssumptions explained

    How to use

    1. Enter the member length.
    2. Set the temperature change in kelvin (the same number as °C difference).
    3. Enter the expansion coefficient α, or read it from the material table.
    4. Enter Young’s modulus for the restrained-stress calculation.
    5. Set the cross-section area to convert stress into anchor force.
    6. Compare the free expansion with the restrained stress before deciding on a joint.

    The formula

    ΔL=αLΔT,ε=αΔT,σ=EαΔT,F=σA\Delta L = \alpha L \Delta T, \qquad \varepsilon = \alpha \Delta T, \qquad \sigma = E \alpha \Delta T, \qquad F = \sigma A

    Reference: Standard isotropic thermoelasticity; α and E values from ASM Handbook and MatWeb material tables.

    Worked example

    12 m steel member, 60 K rise (default inputs)

    Inputs
    • Length 12 m.
    • Temperature change 60 K.
    • α = 12 µm/m·K, E = 200 GPa.
    • Section area 2,500 mm².
    Calculation path
    1. 1

      Expansion: 12×10⁻⁶ × 12 × 60 = 8.64 mm.

    2. 2

      Strain: 12×10⁻⁶ × 60 = 720 microstrain.

    3. 3

      Restrained stress: 200×10⁹ × 720×10⁻⁶ = 144 MPa.

    4. 4

      Anchor force: 144 MPa × 2,500 mm² = 360 kN.

    Result

    8.64 mm growth · 720 µε · 144 MPa if fully restrained · 360 kN of anchor force.

    Interpreting the result

    The 8.64 mm of growth is modest, but the 144 MPa of stress it would generate is not — that is over half the yield strength of ordinary structural steel, produced by a warm day. Notice that the stress does not depend on the length: a 1 m member and a 100 m member develop the same stress if both are fully restrained, because the strain is the same. Only the force changes, through the area.

    Assumptions & limitations

    • The temperature change is uniform through the member. A gradient causes bending as well as extension.
    • The material is isotropic, so α is the same in all directions.
    • Behaviour is linear elastic; once yield is reached, the stress relaxes rather than growing further.
    • Restraint is total. Partial restraint produces a stress somewhere between zero and EαΔT.
    • α and E are constant over the temperature range, which fails at high temperature and through phase changes.

    Frequently asked questions

    Why does length not affect the restrained stress?

    Because stress is proportional to strain, and strain is αΔT — no length term. Length affects the free expansion and, through the cross-section, the force, but not the stress.

    What is an expansion joint for?

    It removes the restraint, letting the member grow freely so the stress never develops. The joint must accommodate the full calculated ΔL plus a margin for temperature extremes.

    Does this apply to plastics and composites?

    The formula holds, but α for polymers is 5–10 times higher and often anisotropic in composites. Thermal stress in bonded dissimilar materials is a common failure mode.

    How much stress does steel develop per kelvin?

    About 2.4 MPa per kelvin (200 GPa × 12×10⁻⁶). Fifty kelvin of restraint is 120 MPa, which is why unjointed steel structures need careful detailing.

    Why does Invar behave differently?

    Its α is about 1.2 µm/m·K, a tenth of steel’s, because of its nickel-iron composition. That makes it valuable for precision instruments, at a significant cost.

    What about cooling?

    Enter a negative ΔT. The member contracts, and if restrained it develops tensile stress instead of compressive. Both directions matter in practice.

    Methodology last reviewed 2026-10-18. Results are informational and not financial or engineering advice — see our disclaimer.