    Calculates locally in your browser · saturated steam line sizing
    Process / steam

    Steam pipe sizing

    Steam is sized on velocity rather than on pressure drop, because the density changes by orders of magnitude with pressure: a line that is fine at 10 bar is sonic at 1 bar for the same mass flow. The specific volume therefore drives everything, and it comes from the saturated steam table rather than from the ideal gas law.

    VelocityGoodT sat180 °CFlash15.3%
    Line size
    DN 80
    74 mm required at 25 m/s
    Actual velocity
    21.5 m/s
    within the usual band
    Specific volume
    0.1944 m³/kg
    at 180 °C
    Volume flow
    389 m³/h
    2,000 kg/h of mass flow
    Velocity sizing
    Steam is sized on velocity because the density changes by orders of magnitude with pressure.
    DN 80
    Velocity sizing
    StepValueNote
    Mass flow2,000 kg/has entered
    Pressure10.0 bar abssaturation at 180 °C
    Specific volume0.1944 m³/kgsaturated vapour
    Target velocity25 m/s15–25 m/s is the usual band
    Volume flow389 m³/hmass × specific volume
    Required bore74.2 mmfrom A = ṁv/V
    Nominal sizeDN 80next standard size up
    Actual velocity21.5 m/sacceptable
    Flash at the trap15.3%dropping to 1.0 bar
    Flash per tonne153 kgrecoverable

    At 10.0 bar the steam is 180 °C with a specific volume of 0.194 m³/kg, so 2,000 kg/h needs a 80 mm line to stay near 25 m/s.

    Inspect the model
    Choose a quick result view, a scaled comparison, or the complete diagnostic set.
    Bore against mass flow
    The bore goes as the square root of the flow, so doubling the flow needs 41% more diameter.
    Bore against mass flow0.00033.2366.4599.68132.90166.13500 kg/h500 kg/h1000 kg/h1000 kg/h2000 kg/h2000 kg/h4000 kg/h4000 kg/h8000 kg/h8000 kg/hBore, mm
    Specific volume against pressure
    Low-pressure steam is bulky: a line that is fine at 10 bar is sonic at 1 bar for the same mass flow.
    Specific volume against pressure0.0000.4000.8001.201.602.001.691 bar1 bar0.8862 bar2 bar0.3755 bar5 bar0.19410 bar10 bar0.13215 bar15 bar0.10020 bar20 barm³/kg
    Canonical equations
    The exact relationships implemented by this engine.

    A = ṁ v / V · Mass flow × specific volume ÷ velocity.

    d = √(4A/π) · Then the next nominal size.

    v_g(P) · From the saturated table.

    (h_f1 − h_f2) / h_fg2 · Recovered at the trap.

    engineering methodology

    A clear path from inputs to results.

    Steam is sized on velocity rather than on pressure drop, because the density changes by orders of magnitude with pressure: a line that is fine at 10 bar is sonic at 1 bar for the same mass flow. The specific volume therefore drives everything, and it comes from the saturated steam table.

    Step-by-step methodWorked exampleAssumptions explained

    How to use

    1. Enter the steam flow in kg/h.
    2. Set the line pressure and the target velocity.
    3. Read the required bore and the nominal size.
    4. Check the actual velocity in the selected size.

    The formula

    A=m˙ vgV  ;  d=4AπA = \frac{\dot m\, v_g}{V} \;;\; d = \sqrt{\frac{4A}{\pi}}

    Reference: IAPWS-IF97 saturated steam properties; velocity sizing practice from Spirax Sarco and Crane TP-410.

    Worked example

    2,000 kg/h at 10 bar

    Inputs
    • 2,000 kg/h of saturated steam.
    • 10 bar absolute, target velocity 25 m/s.
    Calculation path
    1. 1

      At 10 bar the saturation temperature is 179.9 °C and the specific volume is 0.1944 m³/kg.

    2. 2

      The volume flow is 2,000 × 0.1944 = 389 m³/h.

    3. 3

      At 25 m/s that needs a bore of 74.2 mm.

    4. 4

      The next nominal size is DN 80, which runs at 21.5 m/s.

    5. 5

      At 1 bar the same mass flow would need a bore more than twice as large.

    Result

    74.2 mm required · DN 80 · 21.5 m/s actual.

    Interpreting the result

    The specific volume is the whole calculation. Because it varies as roughly 1/p, halving the pressure roughly doubles the pipe area for the same mass flow — which is why low-pressure steam mains are so much larger than the high-pressure lines that feed them.

    Assumptions & limitations

    • Saturated steam, dry.
    • Velocity sizing, not pressure-drop sizing.
    • A single nominal size with no allowance for fouling.
    • Standard wall thickness and no superheat.

    Frequently asked questions

    What velocity should I use?

    15–25 m/s for saturated steam in distribution. Above 40 m/s the line starts to erode and the noise becomes the constraint.

    Does superheated steam need a bigger pipe?

    Yes for the same mass flow, because its specific volume is larger. It also tolerates a higher velocity, which partly offsets it.

    Why does the actual velocity differ from the target?

    Because nominal sizes are discrete. The selected pipe is always at least as large as the requirement, so the actual velocity is at or below the target.

    Why not size on pressure drop?

    You can, and for a long main you should. Velocity sizing is the quick check that keeps erosion and noise under control.

    What about wet steam?

    Wetness increases the volume and carries water slugs that erode the pipe. A separator at the boiler outlet and traps at low points are the fix, not a bigger pipe.

    Methodology last reviewed 2026-10-22. Results are informational and not financial or engineering advice — see our disclaimer.