Skip to content

    Under active development. New calculators and features ship every week. Everything currently runs free while the site matures — pricing pages are a preview, checkout is not open yet.

    Calculates locally in your browser · Rankine cycle with reheat
    Thermodynamics / power cycles

    Rankine cycle with reheat

    Reheat expands the steam twice: once to an intermediate pressure, back to the boiler for a second pass through the superheater, then to the condenser. It raises the mean temperature of heat addition — and, more usefully, it dries the exhaust, which is what actually limits how high the boiler pressure can go in a simple cycle.

    QualityDry enoughGain1.8 ptReheat3.0 bar
    Efficiency
    29.5%
    +1.8 points over simple
    Exhaust quality
    0.966
    simple cycle 0.781
    Net work
    966 kJ/kg
    185 + 782 across two stages
    Heat input
    3276 kJ/kg
    boiler plus reheater
    Six states, two expansions
    The reheater sits between the two turbine stages and lifts the enthalpy back up before the second.
    29.5%
    Six states, two expansions
    Stateh (kJ/kg)Note
    1 — turbine inlet2777boiler exit
    2 — first stage exit2592at the reheat pressure
    3 — reheater exit3284back to the reheat temperature
    4 — second stage exit2503at the condenser pressure
    5 — condenser exit192saturated liquid
    6 — pump exit193.0feedwater
    High-pressure work185 kJ/kgh1 − h2
    Low-pressure work782 kJ/kgh3 − h4
    Net work966 kJ/kgturbine less pump
    Heat input3276 kJ/kgh1 − h6 plus h3 − h2
    Efficiency29.5%reheat cycle
    Simple cycle27.7%same pressures, no reheat

    Reheat lifts efficiency by 1.8 points and the exhaust from 78.1% to 96.6% dry. The dryness is usually the more important of the two: below 88% the last stages erode, and reheat is how a high-pressure cycle stays above that line.

    Inspect the model
    Choose a quick result view, a scaled comparison, or the complete diagnostic set.
    Efficiency against reheat pressure
    There is an optimum: too low and the reheat does little, too high and the first stage is barely used.
    Efficiency against reheat pressure0.0006.6313.2619.8926.5333.160.5 bar0.5 bar1 bar1 bar2 bar2 bar3 bar3 bar5 bar5 barEfficiency %
    Work split
    Reheat moves work from the high-pressure stage to the low-pressure one.
    Work split0.000227.87455.74683.60911.471139.34185.07High pressureHigh pressure781.71Low pressureLow pressure965.54NetNetkJ/kg
    Canonical equations
    The exact relationships implemented by this engine.

    w₁ = h₁ − h₂ · To the reheat pressure.

    q_rh = h₃ − h₂ · Back to the reheat temperature.

    w₂ = h₃ − h₄ · To the condenser.

    (w₁ + w₂ − w_p)/(q_b + q_rh) · Both heat inputs.

    engineering methodology

    A clear path from inputs to results.

    Reheat expands the steam twice: once to an intermediate pressure, back to the boiler for a second pass through the superheater, then to the condenser. It raises the mean temperature of heat addition and, more usefully, dries the exhaust.

    Step-by-step methodWorked exampleAssumptions explained

    How to use

    1. Set the boiler, reheat and condenser pressures.
    2. Choose the reheat temperature.
    3. Enter the turbine and pump efficiencies.
    4. Read the efficiency gain and the exhaust quality.

    The formula

    η=(h1−h2)+(h3−h4)−wp(h1−h6)+(h3−h2)\eta = \frac{(h_1 - h_2) + (h_3 - h_4) - w_p}{(h_1 - h_6) + (h_3 - h_2)}

    Reference: Saturated properties from IAPWS-IF97 with a constant-cp superheat approximation.

    Worked example

    10 bar, reheat at 3 bar to 400 °C

    Inputs
    • Boiler 10 bar, reheat 3 bar, condenser 0.1 bar.
    • Reheat to 400 °C, turbine 85%, pump 80%.
    Calculation path
    1. 1

      The first expansion runs from 2,777 kJ/kg to 2,592 kJ/kg at 3 bar.

    2. 2

      Reheating to 400 °C lifts the enthalpy to 3,284 kJ/kg.

    3. 3

      The second expansion runs to 2,503 kJ/kg at 0.1 bar.

    4. 4

      Net work is 966 kJ/kg against a heat input of 3,276 kJ/kg.

    5. 5

      Efficiency is 29.5% against 27.7% for the simple cycle, and the exhaust is 96.6% dry rather than 78.1%.

    Result

    29.5% · +1.8 points · exhaust 96.6% dry.

    Interpreting the result

    The quality gain is the important one. A simple cycle from 10 bar to 0.1 bar ends at 78% dry, which would destroy the last turbine stages; reheat brings it to 96.6%. That is why reheat is universal on high-pressure plant and why the efficiency gain alone would not justify it.

    Assumptions & limitations

    • One reheat, back to a stated temperature.
    • Constant-cp superheat approximation, cp ≈ 2.1 kJ/kg·K.
    • No pressure loss in the reheater or crossover piping.
    • No regeneration.

    Frequently asked questions

    Why does reheat improve the exhaust so much?

    Because it adds enthalpy at a high temperature after the first expansion, so the second expansion starts from a much higher enthalpy and ends further inside the wet region — or above it entirely.

    What is the optimum reheat pressure?

    Usually a quarter to a third of the boiler pressure. Lower and the first stage does too little; higher and the reheat adds heat at a temperature too low to help.

    How much does a second reheat add?

    About a third of what the first one gave. Only a few very large plants use two.

    Is the efficiency gain always positive?

    No. Reheating only to saturation adds heat at a low temperature and can reduce efficiency. The gain requires reheating to a high temperature, which is why a real reheater sits in the furnace gas path.

    Does reheat replace superheat?

    No, they do different jobs. Superheat raises the turbine inlet temperature; reheat restores it part-way through the expansion.

    Methodology last reviewed 2026-10-22. Results are informational and not financial or engineering advice — see our disclaimer.