    Economic insulation thickness

    Insulation is a capital cost that buys a running saving, so the right thickness is where the marginal cost of another millimetre equals the marginal energy it saves — not the thickest that will fit. There is also a curiosity: below the critical radius (k/h) adding insulation increases heat loss, because the extra surface area outweighs the extra resistance.

    Critical radius4.0 mmCriticalAbovek0.040
    Economic thickness
    150 mm
    where marginal cost meets marginal saving
    Heat loss
    23.2 W/m
    from 408 W/m bare
    Annual energy saving
    $185
    6000 hours a year
    Total annual cost
    $15
    $11 energy + $4 capital
    The cost curve
    Energy cost falls with thickness and capital cost rises; the sum has an interior minimum.
    150 mm
    The cost curve
    ThicknessHeat lossEnergyCapitalTotal
    0 mm408.4 W/m$196$0$196
    25 mm71.2 W/m$34$0$34
    50 mm44.6 W/m$21$1$22
    75 mm34.5 W/m$17$1$18
    100 mm29.0 W/m$14$2$16
    125 mm25.6 W/m$12$3$15
    150 mm23.2 W/m$11$4$15
    175 mm21.5 W/m$10$5$15
    200 mm20.1 W/m$10$6$15
    225 mm19.0 W/m$9$7$16
    250 mm18.1 W/m$9$8$17
    275 mm17.3 W/m$8$10$18
    300 mm16.7 W/m$8$12$20

    The economic thickness is 150 mm, where 11 of annual energy cost meets 4 of annualised insulation cost. Beyond that the saving per millimetre falls below its price.

    Inspect the model
    Choose a quick result view, a scaled comparison, or the complete diagnostic set.
    Heat loss against thickness
    The first few millimetres do most of the work; the curve flattens quickly.
    Heat loss against thickness0.00091.48182.97274.45365.93457.4200252550507575100100125125150150175175200200225225250250275275300300W/m
    Annual cost against thickness
    Energy falls, capital rises, and the total is U-shaped — the minimum is the economic thickness.
    Annual cost against thickness0.00043.9187.82131.74175.65219.5600252550507575100100125125150150175175200200225225250250275275300300EnergyCapitalTotal
    Canonical equations
    The exact relationships implemented by this engine.

    q = ΔT / (ln(r₂/r₁)/2πk + 1/2πr₂h) · Per metre of pipe.

    rc = k/h · Below it, insulation increases loss.

    energy + capital × CRF · The curve to minimise.

    i(1+i)ⁿ / ((1+i)ⁿ − 1) · Capital recovery factor.

    engineering methodology

    A clear path from inputs to results.

    Insulation is a capital cost that buys a running saving, so the right thickness is where the marginal cost of another millimetre equals the marginal energy it saves — not the thickest that will fit.

    Step-by-step methodWorked exampleAssumptions explained

    How to use

    1. Enter the pipe diameter and the insulation conductivity.
    2. Set the fluid and ambient temperatures and the surface film coefficient.
    3. Add the installed cost, energy price, hours and life.
    4. Read the economic thickness and the cost curve.

    The formula

    q=ΔTln⁡(r2/r1)2πk+12πr2hq = \frac{\Delta T}{\dfrac{\ln(r_2/r_1)}{2\pi k} + \dfrac{1}{2\pi r_2 h}}

    Reference: Cylindrical conduction with a surface film coefficient, ASTM C680 and ISO 12241 practice.

    Worked example

    A 100 mm pipe at 150 °C

    Inputs
    • 100 mm outside diameter, k = 0.04 W/m·K.
    • 150 °C fluid, 20 °C ambient, h = 10 W/m²·K.
    • Insulation $300/m³, energy $0.08/kWh, 6,000 hours, 15 years at 6%.
    Calculation path
    1. 1

      Bare, the pipe loses 408 W/m — the only resistance is the surface film.

    2. 2

      At 50 mm of insulation the loss falls to 45 W/m.

    3. 3

      The energy cost falls from $196 a year to $21, while the annualised insulation cost rises from zero to $7.

    4. 4

      At 150 mm the total is lowest: $11 of energy plus $4 of capital.

    5. 5

      Beyond that the capital rises faster than the energy falls, so the curve turns up.

    Result

    150 mm economic · 23 W/m · $15 a year total.

    Interpreting the result

    The critical radius is the counter-intuitive part: below k/h, adding insulation increases heat loss because the extra surface area outweighs the extra resistance. It only happens on small pipes with poor surface coefficients, but on a 10 mm instrument line it is real.

    Assumptions & limitations

    • Steady-state, one-dimensional radial conduction.
    • A constant surface film coefficient combining convection and radiation.
    • Insulation cost proportional to volume.
    • No labour that scales with surface area rather than volume.

    Frequently asked questions

    Why is there an optimum at all?

    Because energy cost falls with thickness while capital cost rises. The minimum of the sum is the economic thickness, and it moves with the energy price rather than with the pipe.

    Does doubling the energy price double the thickness?

    Roughly, yes — the optimum scales close to linearly with the square root of the price ratio, so a doubling buys about 40% more thickness.

    What about the surface temperature?

    It matters for personnel protection: 60 °C is the usual limit for a touchable surface, which can require more thickness than the economic calculation does.

    What is the critical radius?

    k/h. Below it, the insulation adds more surface area than resistance and the heat loss goes up. For mineral wool on a small pipe it can be 30 mm or more.

    Should I just insulate as much as possible?

    No. Beyond the economic thickness the extra capital never repays, and on a retrofit the labour often dominates the material anyway.

    Methodology last reviewed 2026-10-22. Results are informational and not financial or engineering advice — see our disclaimer.